« Back to Search

HPI’s Chevron strain gages are designed with two active elements oriented at right angles (90°) to each other, bonded to a single shim. These gages are most popular for the ease and accuracy of Poisson’s Ratio measurements. (A material loaded in one direction will undergo strains perpendicular to the direction of the load as well as parallel to it. The ratio of the transverse strain to the longitudinal strain is called Poisson’s Ratio.)

Our waterproof gages are specifically designed to evaluate and monitor live-load stresses for railroad, bridge, and other structural applications and are 100% full water immersion tested.

The precision foil gage is bonded to a stainless steel shim, pre-wired and protected with a molded water-proofing material. The stainless steel shim permits easy field installation with any conventional capacitive discharge spot welder.

Instrumentation cable and wiring options can be customized to your specifications. Custom gage sizes and resistance are also available. Please see the table below for options.

Temperature Range: -50°F — 180°F (-45.5°C — 82°C)
Gage Factor (nominal): 2.0

Part Number

Gage Resistance (Nominal)

Gage Factor (Nominal)

Gage Length

Lead Wire

Shim Length

Shim Width

HBWC-12-125-6-VR-HB
Data Sheet (80-807)

120 Ohms

2.0

.125″

Vinyl

1.06″

1.06″

HBWC-12-125-6-GP-TR-HB
Data Sheet (80-806)

120 Ohms

2.0

.125″

Shielded Vinyl

1.06″

1.06″

HBWC-12-125-6-GP-TR-QB
Data Sheet (80-819)

120 Ohms

2.0

.125″

Shielded Vinyl

1.06″

1.06″

HBWC-35-125-6-VR-HB
Data Sheet (80-843)

350 Ohms

2.0

.125″

Vinyl

1.06″

1.06″

HBWC-35-125-6-VR-QB
Data Sheet (80-844)

350 Ohms

2.0

.125″

Vinyl

1.06″

1.06″

HBWC-35-125-6-GP-TR(SS)-HB
Data Sheet (80-845)

350 Ohms

2.0

.125″

Shielded Vinyl

1.06″

1.06″

HBWC-35-125-6-GP-TR(SS)-QB
Data Sheet (80-846)

350 Ohms

2.0

.125″

Shielded Vinyl

1.06″

1.06″

Standard gage configurations can be customized for individual applications
Choose options from the table below for waterproof strain gages

Gage Resistance

12: 120 Ohms
35: 350 Ohms

Gage Length

125: 1/8″ active grid
250: 1/4″ active grid

Temp. Compensation

6: 6 ppm/°F
9: 9 ppm/°F

Pre-Curved Shims

Hoop (Circumferential)
Axial (Longitudinal)

Custom Wiring Options

SS: Stainless steel hypo-tube stress relief between sensor and cable transition
TR: Teflon ribbon stress relief between sensor and cable transition
NT: Sensors with cable integral to sensor shim (no transition)
FB: Full bridge
HB: Half bridge
DR: Dual sensor shims, teflon ribbon stress relief
DS: Dual sensor shims, stainless steel stress relief
FR: Full bridge: 4 active elements on single shim, teflon ribbon stress relief
FS: Full bridge: 4 active elements on single shim, stainless steel stress relief
AMP: Amplified full bridge, gain of X 100 standard (wiring datasheets 80-821 and 80-822)
NW: No waterproofing encapsulation

Instrumentation Cable

GP: General purpose 3 or 4 conductor, shielded vinyl jacket (#22 AWG)
HP: 4 conductor, heavy duty shielded vinyl jacket (#22 AWG)
VR: 3 or 4 conductor, vinyl ribbon (#24 or #30 AWG)
TR: 3 or 4 conductor, teflon ribbon (#30 AWG)
UP: 4 conductor, polyurethane shielded jacket (#22 AWG)
EP: 4 conductor silicone shielded jacket, elevated temp. (#22 AWG)